7. TROUBLESHOOTING
B–63785EN/01
370
(1)Does the other type of manual operation (JOG) work?
(2)Check the CNC status display.
Make the same check as that described in Section 7.1, “Both Manual and
Automatic Operations are Impossible” or 7.2, “Manual (JOG) Operation
is Impossible”.
If “HND” appears when manual handle mode is selected, mode selection
is normal.
If not, it implies that the following mode selection signal is not being
input correctly. Check the mode selection signal, using the PMC
diagnostic function (PMCDGN).
#7
G003
#6 #5 #4 #3 #2 #1
H
#0
Check the signal, using the PMC diagnostic function (PMCDGN).
#7
G010
#6 #5 #4 #3
HS3D
#2
HS3C
#1
HS3B
#0
HS3A
#7
HS2DG011
#6
HS2C
#5
HS2B
#4
HS2A
#3
HS1D
#2
HS1C
#1
HS1B
#0
HS1A
If selecting the manual handle feed axis selection switch causes the above
signals to be input as listed below, the operation is normal.
Selected axis HSnD HSnC HSnB HSnA
No axis
First
Second
Third
Fourth
Fifth
Sixth
Seventh
Eighth
0
0
0
0
0
0
0
0
1
0
0
0
0
1
1
1
1
0
0
0
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
NOTE
In the above table, “n” stands for the number for each
manual pulse generator (MPG). It represents the selection
signal for up to three manual pulse generators. A 4–bit code
(A to D) is used for axis selection.
7.3
HANDLE FEED (MPG)
OPERATION IS
IMPOSSIBLE
[Point]
[Cause and action]
1. If the other type of
manual operation (JOG)
does not work
2. If manual handle
operation (MPG) does
not work but JOG does
(1) Check the CNC status
display (in the left–hand
part of the screen).
(2) The manual handle feed
axis selection signal
has not been input.