B–63785EN/01
3. DATA INPUT/OUTPUT
233
Specify the general items for the communication protocol. The table
below lists the items, along with corresponding parameters.
Item name Parameter Option (parameter setting)
TV CHECK TVC (No.0000#0) ON (1)/OFF (0)
TV (COMMENT) CTV (No.0000#1) ON (0)/OFF (1)
IN/OUT CODE ISP (No.0000#2)
EIA (No.0000#4)
EIA (#2=0/1, #4=1)
ISO (#2=0, #4=0)
ASCII (#2=1, #4=0)
EOB CODE NCR (No.0000#3) LF CR CR(0)/LF(1)
F.G. INPUT
F.G. OUTPUT
B.G. INPUT
B.G. OUTPUT
(No.0020)
(No.0021)
(No.0022)
(No.0023)
RS232–C C1 (1)
RS232–C C2 (2)
RS232–C C3 (3)
MEMCARD (8)
RMTBUF (10)
RS422 C1 (13)
OPEN CNC1 (15) (DNC operational interface)
OPEN CNC2 (16) (UP LOAD/DOWN LOAD interface)
RS232–C C4 (20)
RS422 C2 (21)
Set the communication conditions for each of RS–232C and RS–422
channels. The device type, number of stop bits, and baud rate are
specified using the following parameter sets and are allocated to channels
for which device numbers are set using parameters Nos. 5001 to 5003 and
5013.
Parameter set 1: parameters Nos. 5110, 5111, and 5112
Parameter set 2: parameters Nos. 5120, 5121, and 5122
.
.
.
Parameter set 9: parameters Nos. 5190, 5191, and 5192
Item name Parameter Setting
DEVICE TYPE (No.5110, 5120, 5130)
(No.5140, 5150, 5160)
(No.5170, 5180, 5190)
1 to 8
STOP BIT (No.5111, 5121, 5131)
(No.5141, 5151, 5161)
(No.5171, 5181, 5191)
1/2
BAUD RATE (No.5112, 5122, 5132)
(No.5142, 5152, 5162)
(No.5172, 5182, 5192)
1 to 12
(50, 100, 110, 150, 200, 300, 600,
1200, 2400, 4800, 9600, 19200 bps)
Brief description of the item to which the cursor is positioned, such as the
possible settings.
D BASIC SETTING
D RS–232C, RS422
SETTING
D [HINT]