B–63785EN/01
5. DIGITAL SERVO
329
On the amplifier setting screen, the following item can be specified:
D AXIS NO. (controlled axis number)
For this item, enter a value between 0 and the maximum number of
controlled axes. If a number that falls outside this range is entered, the
warning message “DATA IS OUT OF RANGE” appears. After
entering controlled axis numbers using the amplifier setting screen,
enter data using the axis setting screen. If the entered controlled axis
number is duplicate, the warning message “DATA IS INCORRECT”
appears when soft key [AUTO SET] is pressed to assert the entered
value. In this case, no value can be entered for the parameter.
On the axis setting screen, the following items can be specified:
D M1 (connector number for pulse module 1)
For an axis that uses pulse module 1, enter a connector number using
a number in the range of between 1 and the maximum number of axes
for pulse module 1. For an axis that does not use pulse module 1, enter
0. If a number that falls outside the valid range is entered, the warning
message “DATA IS OUT OF RANGE” is displayed.
D M2 (connector number for pulse module 2)
For an axis that uses pulse module 2, enter a connector number using
a number in the range of between 1 and the maximum number of axes
for pulse module 2. When pulse module 2 need not be used, enter 0.
If a number that falls outside the valid range is entered, the warning
message “DATA IS OUT OF RANGE” is displayed.
D 1DSP
When the functions listed below are used, enter 1 for the following
axes, each of which exclusively uses hardware which would normally
be shared by two axes. If a number other than 0 or 1 is entered, the
warning message “DATA IS OUT OF RANGE” is displayed.
· High–speed current loop axis
· High–speed interface axis
D SPOS
Enter a spindle number (1 to 4) for setting a spindle positioning axis.
If a number other than 0 to 4 is entered, the warning message “DATA
IS OUT OF RANGE” is displayed.
D Cs AXIS
Enter a spindle number (1 to 4) for setting the Cs contour controlled
axis. If a number other than 0 to 4 is entered, the warning message
“DATA IS OUT OF RANGE” is displayed.
D TANDEM
Enter odd and even numbers for the master and slave axes for tandem
control. These numbers must be consecutive and in the range of
between 1 and the number of controlled axes. If a number that falls
outside the valid range is entered, the warning message “DATA IS
OUT OF RANGE” is displayed.
D EGB
Enter odd and even numbers for the master and slave axes when using
the EGB function. These numbers must be consecutive and in the
range of between 1 and the number of controlled axes. If a number that
falls outside the valid range is entered, the warning message “DATA
IS OUT OF RANGE” is displayed.
D Amplifier setting screen
D Axis setting screen