B–63785EN/01
7.TROUBLESHOOTING
423
This indicates that a slave station detected an error. The group number
of the slave station that detected the error is indicated by “(yy#0 to yy#4)
– 1.” The error type is indicated by yy#5 to yy#7.
yy#5: The slave detected invalid communication data.
yy#6: The slave detected an error of another type.
yy#7: The slave detected a watchdog or timer error.
Example)
If yy = 83 (hex), yy#0 to yy#4 = 3 and yy#7 = 1.
Thus, “the slave station in group 4 (= 3 + 1) detected a watchdog or
parity error.”
(1)If “yy#5 = 1” in NMI SLC xx:yy:
The slave having group number “(yy#0 to yy#4) – 1)” detected invalid
communication data.
→ First, replace the slave station having the indicated group number.
If the same alarm occurs even after replacement, identify the cause,
using the procedure described in Section 7.5.2.
(2)If “yy#6 = 1” in NMI SLC xx:yy:
The slave having group number “(yy#0 to yy#4) – 1)” detected an error
of another type.
→ First, replace the slave station having the indicated group number.
If the same alarm occurs even after replacement, identify the cause,
using the procedure described in Section 7.5.2.
(3)If “yy#7 = 1” in NMI SLC xx:yy:
The slave having group number “(yy#0 to yy#4) – 1)” detected a
released link.
→ First, replace the slave station having the indicated group number.
If the same alarm occurs even after replacement, identify the cause,
using the procedure described in Section 7.5.2.3.
This indicates that a link between the NC and a slave has been released.
The most likely causes are:
(1)The slave station was turned of.
→ The most likely causes are a momentary interruption of the slave
station power supply or insufficient power supply capacity. Check
whether each slave station’s power supply.
(2)The I/O Link cable was disconnected
→ The most likely cause is that the connector is defective. Check that
the connector is inserted securely.
(3)Any other cause
→ Identify the cause, using the procedure described in Section 7.17.2.
7.17.2.2
If “xx#1=1” in NMI SLC
xx:yy
7.17.2.3
If “xx#2=1” in NMI SLC
xx:yy