APPENDIX
B–63785EN/01
B. ALARM LIST
483
Number Message Contents
IO0001 FILE ACCESS ERROR The resident–type file system could not be accessed as an error
occurred in the resident–type file system.
IO0002 FILE SYSTEM ERROR The file could not be accessed as an error occurred in the CNC file
system.
IO0030 CHECK SUM ERROR The checksum of the CNC part program storage memory is incorrect.
IO0032 MEMORY ACCESS OVER RANGE Accessing of data occurred outside the CNC part program storage
memory range.
Number Message Contents
PW0000 POWER MUST BE OFF A parameter was set for which the power must be turned OFF then ON
again.
PW0100 ILLEGAL PARAMETER (S–COMP.) The parameter for setting straightness compensation is incorrect.
PW0102 ILLEGAL PARAMETER (I–COMP.) The parameter for setting slope compensation is incorrect. This alarm
occurs in the following cases:
· When the number of pitch error compensation points on the axis on
which slope compensation is executed exceeds 128 between the
most negative side and most positive side
· When the size relationship between the slope compensation point
Nos. is incorrect
· When the slope compensation point is not located between the most
negative side and most positive side of pitch error compensation
· When the compensation per compensation point is too small or too
great.
PW0103 ILLEGAL PARAMETER (S–COMP.128) The parameter for setting 128 straightness compensation points or the
parameter compensation data is incorrect,
B.7
FILE ACCESS
ALARM (IO ALARM)
B.8
POWER MUST BE
TURNED OFF ALARM
(PW ALARM)