10.STEP SEQUENCE FUNCTION B-63983EN/02
- 1014 -
(2) Operations using soft keys
(a) [LIST] Switch to the program list display screen
Switches the screen display to the program list display
screen.
(b) [SEARCH] Step search
Searches for a step. When you press the [SEARCH] soft
key after entering a step number or symbol name, the step
corresponding to the entered character string is found, and
the display is updated so that the found step is placed at the
start.
(c) [RESET] Abnormal state reset
Resets abnormal states that have occurred in all time
monitoring operations.
For individual resetting, reset a desired monitoring
operation on the time monitor setting screen.
(d) [MONIT] Switch to the time monitor setting screen
Switches the screen display to the time monitor setting
screen.
(e) [<]
Switches the screen display to the PMC ladder menu.
(3) Screen operations using other keys
Page keys
The page keys can be used to switch from one display page
to another. A program can be searched using the down
cursor key following the step number or symbol name
entered.
Soft keys for step sequence state display screen (global)
Switch to program list screen Switch to time monitor setting screen
Step search Abnormal state reset