B-63983EN/02 7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE])
- 765 -
(4) Example of trace result output (For view comfort, tab settings are
made in several places. In actual data output, however, no tab
settings are made.)
‘PMC TRACE DATA’
‘Edition’, 1
‘Setting’, , ,
1,‘Sampling mode’, 2, ‘SIGNAL TRANSITION’
2,‘Sampling resolution’, 8, ‘MSEC’
3,‘Sampling time’, 2000,
4,‘Stop condition’, 3, ‘TRIGGER’
5,‘Stop trigger address’, ‘X10.0’, ‘SYMBOL1’
6,‘Stop trigger mode’, 1, ‘RISING EDGE’
7,‘Stop trigger position’, 50(1250/2500), ‘%’
8,‘Sampling condition’, 1, ‘TRIGGER’
9,‘Sampling trigger address’, ‘X10.1’, ‘SYMBOL2’
10,‘Sampling trigger mode’, 3, ‘BOTH EDGE’
‘Address’,‘R0000.0’, ‘R0000.1’, ‘R0000.2’, ‘R0000.3’, ‘R0000.4’, ‘R0000.5’,
‘R0000.6’, ‘R0000.7’, ‘R0001.0’, R0002.0’
‘Symbol’, ‘ZRN_M’ , , , ‘*SPA1’ , ‘*SPA2’, ‘MX-RD’,‘RSTN’, ‘RSTMA’,
‘MO1X’, ‘MO2X’
‘Comment’, ‘ZRN MODE’, ’TIME CNT.AUX1(MEM)’ , , , , ‘READ
STROBE’, ‘NORMAL RESET PB’, ‘INIT_M&RSTM (RST->MACRO)’,
‘OPTIONAL STOP1’,’OPTIONAL STOP2’
‘Check’, 0, 1, 1, 1, 1, 1, 0, 1, 1, 1
‘Data’,‘R0000.0’, ‘R0000.1’, ‘R0000.2’, ‘R0000.3’, ‘R0000.4’, ‘R0000.5’,
‘R0000.6’, ‘R0000.7’, ‘R0001.0’, ‘R0002.0’
-6, 1,0,0,0,0,0,0,0,0,0
-5, 0,0,0,0,0,1,1,1,1,1
-4, 1,1,1,1,1,0,0,0,0,0
-3, 0,1,0,1,0,1,0,1,0,1
-2, 0,0,1,1,0,0,1,1,0,0
-1, 1,1,0,0,0,0,1,1,1,1
0, 1,1,1,1,1,1,1,1,1,1
1, 0,0,0,0,0,0,0,0,0,0
2, 1,0,0,0,0,0,0,0,0,0
3, 0,0,0,0,0,1,1,1,1,1
4, 1,1,1,1,1,0,0,0,0,0
NOTE
NOTE
With the multi-PMC system, this data is output in
the format: "PMC number" + ":" + "address".
Example: '2:R0000.0'