Series 30i/31i/32i-MODEL A
PMC Supplemental Programming Manual
01 05.5.30
H. Yonekura
New registration
B-63983EN/02-5
EDIT
DATE
DESIG.
DESCRIPTION
11/46
DRAW.NO.
NOTE
1 This PMC is used for Dual Check Safety function (option). See "Dual Check Safety
Operators Manual(B-64004EN)" for details.
2 The extra relay is common memory for the multi-PMC function. To put it another
way, its size covers all of the first, second, and third PMCs. And, it can be used as
nonvolatile memory by option (except PMC/L).
3 No extra relay is available for DCS PMC.
4 The message display relay is ineffective in DCS PMC because the message display
function is unavailable in it.
5 This area is used to specify the precision of the variable timer. Do not use this area in
user programs.
6 To use all of data table area as nonvolatile memory with PMC Memory-B in 2nd PMC,
please add the "PMC nonvolatile data table area expansion (7KB)" option. If this
option is not added, the expanded data table area (D3000 to D9999) is not kept after
rebooting CNC.
7 To use all of data table area as nonvolatile memory with PMC Memory-C in 1st PMC,
please add the "PMC nonvolatile data table area expansion (10KB)" option. If this
option is not added, the expanded data table area (D10000 to D19999) is not kept
after rebooting CNC.