3.I/O LINK B-63983EN/02
- 154 -
Connection panel I/O modules
For signal mapping of connection panel I/O modules, refer to the
connection manual (hardware) for the CNC used as the I/O Link
master.
Assignment data is described below for each configuration of basic
and expansion modules.
CAUTION
Always connect expansion modules 1, 2, and 3 in this
order closely when required. Any intermediate
expansion module cannot be skipped.
Basic
module
JD1B
JD1A
Expansion
module 1
Expansion
module 2
You may want to make the above setting so that
expansion module 1 is not mounted to connect it later
and connection information of only expansion module
2 is assigned, but the setting is disabled.
(1) Only basic module
24 input points, 16 output points
Basic
module
JD1B
JD1A
(a) When DO alarm detection is not used
· When no manual pulse generator is used
Input: X=CM03I, output: Y=CM02O
(b) When DO alarm detection is used
· Regardless of the number of manual pulse generators
Input: X=CM16I, output: Y=CM02O