Series 30i/ 31i/ 32i-MODEL A
PMC Supplemental Programming Manual
01 04.12.27
S. Hasegawa
New registration
B-63983EN/02-3
EDIT
DATE
DESIG.
DESCRIPTION
14/73
DRAW.NO.
Fig 3.3.3 (a) Example of using 2 PMCs and 2 I/O Link Channels
NOTE
1. Up to 2 blocks are available in one channel.
2. Up to 16 groups of slaves can be connected to total
of first and second block. The total number of I/O
points occupied by all slaves connected to total of
first and second block is up to 1024 points for each
of input and output. (For details of I/O points, refer
to "FANUC I/O Unit-MODEL A Connection and
Maintenance Manual" (B-61813E)).
3. When second block is used and any alarm occurs,
group no of the alarm message is displayed
according to the I/O device wiring group no.
4. When second block is used, the selectable I/O Link
assignment function is available in each block
independently.
5. The OVERRIDE function of the forced input/output
function is available even if second block is used.
6. When second block is used, it is recommended to
enable the I/O Link connection check function to
prevent a malfunction about the mistake of the
setting.
Setting method
To use the second block, see the following procedure.
(1) I/O module assignment
1st PMC
X/Y0 to 127
X/Y200 to 327
2nd PMC
Channel 1
~ ~
~
Grou
0 Grou
n
Grou
0 Grou
1 Grou
2 Grou
n
Grou
0 Grou
n
1st Block 2nd Block
Channel 2
X/Y0 to 127