B-63983EN/02 5.WINDOW FUNCTIONS
- 621 -
NOTE
Customized data 5 to 20 can be written to memory
when the "tool management function customized
data extension (5 to 20)" option is present.
Customized data 5 to 40 can be written when the
"tool management function customized data
extension (5 to 40)" option is present.
[Input data structure]
Top address + 0
+2
+4
+6
+8
+10
(Function code)
335
(Completion code)
-
Need not be set
(Data length)
1, 2, 4
(Data number)
Cartridge number
(Data attribute)
Data type
(Data number 2)
Pot number
+12
+14
(Detailed completion code)
-
(Need not be set)
(Data area)
1, 2, 4
[Completion codes]
0: The processing has been executed normally.
2: The data length is invalid.
3: The specified cartridge number, pot number, or tool management
data number is out of the range.
4: The specified data type is invalid.
5: The input data is invalid.
6: The necessary option is not found.
7: The area is protected.