B-63983EN/01 2.PMC SPECIFICATIONS
- 121 -
Multi-path PMC interface
11932 Multi-path PMC interface
NOTE
Once this parameters is re-set, it is necessary to turn
the power off and on again.
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0, 1, 2, 3
Select the PMC path to use the Multi-path PMC interface.
Setting Meaning
0 Not use the Multi-path PMC interface
1 Use the Multi-path PMC interface between 1ST and 2ND
PMC.
2 Use the Multi-path PMC interface between 1ST and 3RD
PMC.
3 Use the Multi-path PMC interface between 2ND and 3RD
PMC.
CAUTION
When you setting a inappropriate value to this
parameter, the PMC alarm "ER57 MULTI-PATH
PMC I/F ASSIGNMENT ERROR" occurs and all
PMC paths are stopped.
Then, the specified PMC path is not available, the
PMC alarm "ER57 MULTI-PATH PMC I/F
ASSIGNMENT ERROR" occurs and all PMC paths
are stopped, too.