Series 30i/ 31i/ 32i-MODEL A
PMC Supplemental Programming Manual
01 04.12.27
S. Hasegawa
New registration
B-63983EN/02-3
EDIT
DATE
DESIG.
DESCRIPTION
10/73
DRAW.NO.
[Data type] Integer
[Valid data range] 0, 100 to 103, 200 to 203, 300 to 303
This item specifies input/output addresses for an I/O Link channel.
Table 2.4.3 (g) I/O Link channel input/output addresses
Setting Input/output address
0 Standard setting (see below)
100 X0 to X127/Y0 to Y127 for the first PMC
101 X200 to X327/Y200 to Y327 for the first PMC
102 X400 to X527/Y400 to Y527 for the first PMC
103 X600 to X727/Y600 to Y727 for the first PMC
200 X0 to X127/Y0 to Y127 for the second PMC
201 X200 to X327/Y200 to Y327 for the second PMC
202 X400 to X527/Y400 to Y527 for the second PMC
203 X600 to X727/Y600 to Y727 for the second PMC
300 X0 to X127/Y0 to Y127 for the third PMC
301 X200 to X327/Y200 to Y327 for the third PMC
302 X400 to X527/Y400 to Y527 for the third PMC
303 X600 to X727/Y600 to Y727 for the third PMC
If these parameters are 0, the dual assignment of I/O link channel is
invalid.
CAUTION
If any of these parameters and parameter no. 11910
to 11913 is nonzero, a duplicate number results in
the PMC alarm "ER52 I/O LINK CHANNEL
ASSIGNMENT ERROR", thus disabling all the PMCs
from starting.