Series 30i/ 31i/ 32i-MODEL A
Supplemental PMC Programming Manual
01 04.06.30
T. Matsukawa
New registration
B-63983EN/02-1
EDIT
DATE
DESIG.
DESCRIPTION
25/56
DRAW.NO.
[Input data structure]
Reading axis type parameters for all axes (M=-1, Example for 3 controlled-axes)
Top Address +0 (Function Code)
321
+2 (Completion code)
-
(Need not to be set)
+4 (Data length)
-
(Need not to be set)
+6 (Data number)
N
(N=Parameter number)
Set the parameter number with singed binary format in
four bytes length.
+10 (Data attribute)
-1
All axes
+12 Decimal point position
(2 bytes)
Set the decimal point position of the parameter value
for the 1st axis.
+14 (Data area)
-
(Need not to be set)
+18 Decimal point position
(2 bytes)
Set the decimal point position of the parameter value
for the 2nd axis.
+20 (Data area)
-
(Need not to be set)
+24 Decimal point position
(2 bytes)
Set the decimal point position of the parameter value
for the 3rd axis.
+26
+29
(Data area)
-
(Need not to be set)
[Completion codes]
0: Normal completion
3: The data number is invalid.
4: The data attribute is invalid.