Series 30i/ 31i/ 32i-MODEL A
PMC Supplemental Programming Manual
01 04.12.27
S. Hasegawa
New registration
B-63983EN/02-3
EDIT
DATE
DESIG.
DESCRIPTION
51/73
DRAW.NO.
P The value of the extra relay. Shown in signed decimal
number. Its valid range is –128 to 127.
(Example)
N690000 P-128;
N690001 P100;
・
N699998 P127;
N699999 P0;
%
(b) Table format (Control data part)
[Format]
N635000 Pnn; Number of table groups (1-100)
N635002 Pnnnnnnnn; Table parameter of group 1 (bit format)
N635003 Pn; Data type of group 1 (0,1,2,3)
N635004 Pnnnn; Number of data in group 1 (1-10000)
N635006 Pnnnn; Start address of group 1 (0-9999)
N635010 Pnnnnnnnn; Table parameter of group 2 (bit foramt)
N635011 Pn; Data type of group 2 (0,1,2,3)
N635012 Pnnnn; Number of data in group 2 (1-10000)
N635014 Pnnnn; Start address of group 2 (0-9999)
N Sum of address offset of the control data and 635000.
Its valid range is N63500 to N635798.
P The value of the control data.
“Number of table groups” valid range: 1 - 100
“Table parameter” valid range: 00000000 - 11111111
“Data type” valid range: 0 - 3
Data type Output format of the data
0 Singend decimal number of 1 byte data
1 Singend decimal number of 2 byte data
2 Singend decimal number of 4 byte data
3 8 bit format of 1 byte value
“Number of data in group” valid range: 1 - 10000
“Start address of group” valid range: 0 - 9999
(Example)
N635000 P2;
N635002 P00000000;
N635003 P0;
N635004 P10;
N635006 P0;
N635010 P00000001;
N635011 P0;
N635012 P10;
N635014 P10;
(c) Table format (Extra relay part)
[Format]