2.PMC SPECIFICATIONS B-63983EN/01
- 52 -
NOTE
8 Series 30i can use up to four I/O Link channels (4,096 input points and 4,096 output
points). Series 31i/32i can use up to three I/O Link channels (3,072 input points and
3,072 output points). However, only one I/O Link channel (1,024 input points and
1,024 output points) can be used in the basic function. Using more than one channel
requires installing an I/O Link expansion option for each additional channel.
It is possible to specify which program is used to control a specific I/O Link channel.
See "I/O Link input/output addresses" in Subsection 2.4.3 for details.
9 The capacity of the program storage area varies depending on option settings. See
Tables 2.1.2 (a) to 2.1.2 (d) for details.
10 When you use only the full-size character. The number of comment character
becomes half of the normal specification.
11 These instructions are intended to maintain source-level compatibility with programs
for other models. A program can be created on level 3, but it is not executed.
12 These are the number for extended symbol and comment character. The number of
basic symbol character is 16 and the number of comment character is 30. Refer to
section 1 “Specification of extended symbol and comment“ for details