B-63983EN/02 7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE])
- 661 -
Operation procedure
(1) Press the [STATUS] soft key. The screen shown above appears.
(2) Key in an address whose data to be displayed, then press the
[SEARCH] soft key.
(3) The data starting at the input address is displayed as a bit pattern.
(4) To display the data at another address, press the cursor keys,
page keys, or [SEARCH] soft key.
(5) To modify the status of a signal, switch to the forced I/O screen
by pressing the [FORCE] soft key.
NOTE
The [FORCE] soft key is displayed and usable
when the forced I/O function is enabled. For
details, see Section 6.2.
(6) On the forced I/O screen, an overridden X signal or Y signal is
prefixed by a greater-than sign (>) to indicate the setting of
override.