Series 30i/31i/32i-MODEL A
PMC Supplemental Programming Manual
01 05.03.30
H. Yonekura
New registration
B-63983EN/02-4
EDIT
DATE
DESIG.
DESCRIPTION
64/92
DRAW.NO.
8.3.2 Searching for a Free Pot (Low-speed Response)
[Description]
The nearest free pot (one whose tool management data number is 0) in
the same cartridge is searched for, with reference to the specified pot
position. The main axis and standby positions are not regarded as free
pots.
[Search direction]
−1: Backward
0: No specified
When the search direction is not specified, the nearest free pot
will be searched. If free pots are found at the same distance in
both forward and backward directions, the one found in the
forward directions takes precedence.
1: Forward
[Input data structure]
Top Address +0 (Function code)
330
+2 (Completion code)
-
(Need not to be set)
+4 (Data length)
-
(Need not to be set)
+6 (Data number)
N
(N=Cartridge number)
+8 (Data attribute)
M
(M=Search direction)
-1: Backward, 0: No specified, 1: Forward
+10 (Data number 2)
N2
(N2=Pot number)
+12 (Detailed Completion code)
-
(Need not to be set)
+14
+17
Data area
(4 bytes)
(Need not to be set)