Series 30i/ 31i/ 32i-MODEL A
PMC Supplemental Programming Manual
01 04.12.27
S. Hasegawa
New registration
B-63983EN/02-3
EDIT
DATE
DESIG.
DESCRIPTION
65/73
DRAW.NO.
7.2 PARAMETERS FOR THE PMC SYSTEM
Add the following description at the tails of section “8.2.2 Setting the Display Format of the LADDER
DIAGRAM MONITOR Screen” and section “8.3.2 Setting the LADDER DIAGRAM EDITOR Screen”:
(4) Settings on multi-path PMC system
On the multi-path PMC systems, the Ladder Diagram related
configuration is common to all PMC pathes at first. To make it
independent for each PMC path, set system keep relay K909.4 to 1.
For example, different color settings may make it easier to
recognize the PMC path which the Ladder Diagram on the screen
belongs to.
When you set 1 to K909.4 at the first time, the first PMC path will
inherit the old settings, and the rest path will start with the initial
settings.