Operation Output
Register (R9000)
When ACT=1 and some error occurs in this function, the corresponding
bit of the operation output register is set. In this case, W1 will be turned
off. When ACT=0, the operation output register will not be updated.
Bit 7654321 0
R9000 *
R9000.0: Invalid path or axis number
Example
The example of using this instruction is shown bellow.
- The control data address is R320.
- The setting of machine unit is "mm".
- The setting of minimum unit of data is "IS-B".
- The axis is 3rd axis on 2nd CNC path.
- The settings of machine position are "-800mm" and "123.456
mm".
In this case, you should set the control data using "Extended format" as
following.
Control data R320 0 (2byte) Set zero to this area.
(Extended format) R322 2 (1byte) 2: path2
R323 3 (1byte) 3: 3rd axis
R324 -800000 (4byte) a = -800.000 mm
R328
R331
123456 (4byte) b = 123.456 mm
When ACT=1 and the machine position is equal or grater than -800 mm
and is equal or smaller than 123.456 mm, the W1 is turned on.
SUB 63
PSGN2
R320
ACT W1