6.OPERATING THE PMC SCREEN B-63983EN/02
- 640 -
CAUTION
Set this setting to "NO"(0) before shipment of the
machine. If this setting is left as "YES"(1), the
operator may modify PMC parameters or PMC
signals by mistake. If you want to protect this
setting, please make a sequence that always writes
0 in this bit by your ladder. Or please control the
machine to force to translate into safety state by
sequence program using the way described in
Section 4.15 when the ladder stops.
DATA TBL CNTL SCREEN (K900.7)
If you set "DATA TBL CNTL SCREEN" to "NO", the data table
control screen is not displayed.
IO GROUP SELECTION (K906.1)
If you set "IO GROUP SELECTION " to "SHOW", the setting screen
for the selectable I/O link assignment function is enabled.
HIDE PMC PARAM (K902.6)
If you set "HIDE PMC PARAM" to "YES", functions that are related
to the PMC parameters are protected, as follows:
· The timer, counter, keep relay, and data screens cannot be
displayed.
· The PMC I/O screen cannot output the PMC parameters.
CAUTION
To enter the PMC parameters from the data I/O
screen requires a special operation. For information
about how to enable the input of the PMC
parameters, see "Output from the data I/O screen"
in Subsection 6.2.2.
WARNING
If the sequence program is stopped while the
machine is operating, the machine may cause
unexpected operation. Before stopping the
sequence program, make sure that there is no one
near the machine and that the tool will not collide
with the workpiece or machine. Operating the
machine in any inappropriate fashion can result in
the death of or serious injury to the user. The tool,
workpiece, and/or machine can also be damaged.