7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE]) B-63983EN/02
- 764 -
NOTE
1 Data is not output beyond set sampling addresses.
This means that no blank is output in the item of
'Address'.
2 For an address for which no symbol or no comment
is set, no data is output, but a blank is output in the
column. Commas are not omitted but are output for
up to set sampling addresses.
(d) Trace result data
identifier, sampling-address-1, sampling-address-2, . . . . .
frame-count, data-1, data-2, data-3. . . . .
:
:
:
· identifier Character string data
The character string 'Data' is output.
· frame-count Numeric value
The position where the frame count is 0 is a position
where triggering is performed successfully. If triggering
is unsuccessful, the frame count is 0 at the point where
sampling stopped.
· data Numeric data
The value 0 or 1 is output.
It is assumed that data is output until an EOF (end of
file) appears. Information such as data size is not set.