Series 30i/31i/32i-MODEL A
PMC Supplemental Programming Manual
01 05.03.30
H. Yonekura
New registration
B-63983EN/02-4
EDIT
DATE
DESIG.
DESCRIPTION
88/92
DRAW.NO.
[Completion codes]
0: The processing has been executed normally.
3: The specified cartridge number or shift count is invalid.
4: The specified shift direction is invalid.
6: The necessary option is not found.
[Detailed completion codes]
The detailed completion code is always 0 when the completion code is
other than 3.
When the completion code is 3, the detailed completion code is one of the
following values:
1: The specified cartridge number is invalid.
2: The specified shift count is invalid.
As the shift count, a value not greater than 0 or larger than the
number of cartridge data items is specified.
[Output data structure]
Top Address +0 (Function code)
367
+2 (Completion code)
?
(See above description)
+4 (Data length)
0
+6 (Data number)
N
(N=Same as input data)
+8 (Data attribute)
M
(M=Same as input data)
+10 (Data number 2)
N2
(N2=Same as input data)
+12
+13
(Detailed completion code)
?
(See above description)