4.LADDER LANGUAGE B-63983EN/02
- 354 -
[For multi path control]
(1) 1st path
CTL+0 : 0 or 1
CTL+1 to CTL+3 : Data to be specified for G0 to G2
In case of the extended specification (program number O8 digits
etc.), it sets CTL+1 to CTL+5 as follows.
CTL+1 to CTL+2 : Data to be specified for G0 to G1
CTL+3 to CTL+4 : Data to be specified for G210 to G211
CTL+5 : Data to be specified for G2
(2) 2nd path
CTL+0 : 2
CTL+1 to CTL+3 : Data to be specified for G1000 to G1002
In case of the extended specification (program number O8 digits
etc.), it sets CTL+1 to CTL+5 as follows.
CTL+1 to CTL+2 : Data to be specified for G1000 to G1001
CTL+3 to CTL+4 : Data to be specified for G1210 to G1211
CTL+5 : Data to be specified for G1002
(3) 3rd path
CTL+0 : 3
CTL+1 to CTL+3 : Data to be specified for G2000 to G2002
In case of the extended specification (program number O8 digits
etc.), it sets CTL+1 to CTL+5 as follows.
CTL+1 to CTL+2 : Data to be specified for G2000 to G2001
CTL+3 to CTL+4 : Data to be specified for G2210 to G2211
CTL+5 : Data to be specified for G2002
(4) 4th path
CTL+0 : 4
CTL+1 to CTL+3 : Data to be specified for G3000 to G3002
In case of the extended specification (program number O8 digits
etc.), it sets CTL+1 to CTL+5 as follows.
CTL+1 to CTL+2 : Data to be specified for G3000 to G3001
CTL+3 to CTL+4 : Data to be specified for G3210 to G3211
CTL+5 : Data to be specified for G3002