Series 30i/31i/32i-MODEL A
PMC Supplemental Programming Manual
01 05.03.30
H. Yonekura
New registration
B-63983EN/02-4
EDIT
DATE
DESIG.
DESCRIPTION
11/92
DRAW.NO.
NOTE
1 This PMC is used for Dual Check Safety and handles the safety related signals.
Refer to "Series 30i/31i/32i Dual Check Safety Operators Manual (B-64004EN)" for
details.
2 There is no kind of PMC Memory type in DCS PMC and 32i-A PMC/L.
3 The Step Sequence is unavailable in 2nd PMC even if selecting PMC Memory-B.
4 These instructions are intended to maintain source-level compatibility with programs
for other models. A program can be created on level 3, but it is not executed.
5 NC parameter No. 11930 is used to specify a level-1 execution period. See
Subsection 2.4.3 of PMC Programming Manual for details. Note, however, that it is
impossible to specify a level-1 execution period for each PMC separately.
6 The maximum overall program size (including the maximum number of ladder steps,
symbols/ comments, and messages) varies depending on option settings. See
Table 5.1.2 (a) of this decument and 2.1.2 (a) to 2.1.2 (d) of PMC Programming
Manual for details.
7 For the number of functional instructions, each parenthesized number indicates the
number of all functional instructions, and each non-parenthesized number, the
number of valid functional instructions.
8 It is possible to specify which program is used to control a specific CNC system. See
"Interface between CNC and PMC" in Subsection 2.4.3 of PMC Programming
Manual for details.
9 On series 30i, you can use up to four I/O Link channels (4,096 input points and 4,096
output points). On series 31i/32i, you can use up to three I/O Link channels (3,072
input points and 3,072 output points). The channel number 1 of I/O Link (1,024 input
points and 1,024 output points) is a basic function. The channel number 2 to 4 are
optional function. To use more than one channel of I/O Link, the "I/O Link expansion"
option is necessary for each I/O Link channel.
It is possible to specify which program is used to control a specific I/O Link channel.
See "I/O Link input/output addresses" in Subsection 2.4.3 of PMC Programming
Manual for details.
10 The update cycle of the signals from I/O Link depends on the combination with each
PMC and each I/O Link channel. Refer to the "3.1 WHAT IS THE I/O LINK" of PMC
Programming Manual for details.
11 These are the number for extended symbol and comment character. The number of
basic symbol character is 16 and the number of comment character is 30. Refer to
section 1 "Specification of extended symbol and comment" of PMC Programming
Manual for details.
12 This number is the number of single-byte characters. When you use double-byte
characters as a comment, the number becomes half.
13 The capacity of the program storage area varies depending on option settings. See
Tables 5.1.2 (a) of this document and 2.1.2 (a) to 2.1.2 (d) of PMC Programming