5.WINDOW FUNCTIONS B-63983EN/02
- 572 -
5.6.25 Reading The Tool Life Management Data (Tool Group
Number) (High-speed Response)
(8-digit tool number)
[Description]
This function reads the tool group number in which the specified tool
number is registered. This function supports 8 digits tool number.
[Input data structure]
Top address 0
2
4
6
8
12
(Function code)
200
(Completion code)
-
(Need not be set)
(Data length)
-
(Need not be set)
(Data number)
0
(Data attribute)
M
(M = Tool number)
MAX140
(Data area)
-
(Need not be set)
NOTE
1 When the tool number is set to "0", the tool group
number of the currently used tool is read. If a tool
group number is not specified after the power is
turned ON, tool group number "0" is read.
2 If the same tool belongs to two or more tool groups,
32 tool groups can be read in the maximum. In this
case, 128 bytes are required as the data area in the
maximum.