B-63983EN/02 5.WINDOW FUNCTIONS
- 509 -
5.5.13 Entering Torque Limit Data for the Digital Servo Motor (Low-
speed Response)
[Description]
Torque limit values for the digital servo motor can be entered.
[Input data structure]
Top address + 0
2
4
6
8
10
(Function code)
152
(Completion code)
-
(Need not be set)
(Data length)
2
(Data number)
0
(Data attribute)
M
(M: 1 to n)
Torque limit data
(1 byte)
The high-order byte is always set to
0.
Unsigned binary
<Unit: %>
Values from 0 to 255 correspond to
0% to 100%.
Value
M = 1 to n: Axis No.
CAUTION
Calculate the torque limit data assuming that the
short time rated value is 100%.
Example: To specify a torque limit of 50%, enter
128.
[Completion codes]
0: Torque limit data has been entered normally.
4: The specified data attribute is invalid. That is, a value other than 1
to n (number of axes) was specified, or the specified axis No. was
greater than the number of controlled axes.