2.PMC SPECIFICATIONS B-63983EN/01
- 106 -
2.4 PARAMETERS FOR THE PMC SYSTEM
2.4.1 Setting Parameters
The parameters set up on the PMC SETTING screen are called the
setting parameters. Part of the system keep relays described earlier can
be set up using setting parameters.
This subsection describes the setting parameters for each setup menu.
See Section 9.5 for explanations about the setting screen and how to
use it.
(1) Trace function start (K906.5 0: Manual. 1: Automatic.)
This item specifies whether to allow the trace function to be
executed automatically when the power is turned on. The default
setting is "Manual" (not automatic execution).
(2) Editing permit (K901.6 0: No. 1: Yes.)
This item specifies whether to enable the functions related to
program editing. The default setting is "No" (not to enable).
(3) Save after edit (K902.0 0: No. 1: Yes.)
This item specifies whether to perform an automatic write to flash
ROM after program editing. The default setting is "No" (not to
perform an automatic write).
(4) Memory write permit (K900.4 0: No. 1: Yes.)
This item specifies whether to enable the forcing and override
functions. The default setting is "No" (not to enable).
NOTE
Using the override function requires setting "Override
enable" (K906.0).
(5) Data table GRP setting display (K900.7 0: Yes. 1: No.)
This item specifies whether to display the DATA TABLE
CONTROL screen. The default setting is "Yes" (to display).
(6) PMC parameter view inhibit (K902.6 0: No. 1: Yes.)
This item specifies whether to inhibit the PMC PARAM screens
(TIMER, COUNTER, KEEP RELAY, DATA TABLE screens)
from being displayed and the PMC parameter data from being sent
to the outside. The default setting is "No" (not to inhibit).