B-63983EN/02 9.PMC CONFIGURATION DATA SETTING SCREENS ([PMC CONFIG])
- 931 -
9.8.2 Displaying and Setting Parameters for an FS0 Operator's
Panel
Display and set parameters for using an FS0 operator's panel.
Display screen
· FS0 OPERATOR PANEL Whether to use an FS0 operator's
panel
· KEY DI ADDRESS Start address of actually connected
external DI
· LED DO ADDRESS Start address of actually connected
external DO
· KEY BIT IMAGE ADDRESS Start address of the key image
referenced by user programs
· LED BIT IMAGE ADDRESS Start address of the LED image
generated by user programs
Screen operation
Move to the edit screen
(1) Operation using the soft key
[EDIT] Switch to the edit screen
Switches to the system parameter edit screen.