Series 30i/ 31i/ 32i-MODEL A
Supplemental PMC Programming Manual
01 04.06.30
T. Matsukawa
New registration
B-63983EN/02-1
EDIT
DATE
DESIG.
DESCRIPTION
9/56
DRAW.NO.
input address (X ) or write a digital value to be
converted to an analog value to an output address
(Y ) in word (16-bit) units.
For details of the assignment method, see the assignment method for
each I/O device described later.
Modify the following after “Table 3.2(b) Module names (2)” on ”3.2 Assignment method Setting the module
name”
Table 4.1 (b) Module names (2)
Name
Module name
(actual module name)
Occupied address Specifications
FS04A
4 bytes for input
4 bytes for output
FS08A
8 bytes for input
8 bytes for output
FANUC Series 0-C
(Compatible with the FANUC I/O Link)
FANUC Power Mate-MODEL
A/B/C/D/E/F/H
OC02I 16 bytes for input
OC02O 16 bytes for output
OC03I 32 bytes for input
OC03O 32 bytes for output
FANUC Power Mate-MODEL D/H
12 bytes for input
12 bytes for output
16 bytes for input
16 bytes for output
20 bytes for input
20 bytes for output
24 bytes for input
24 bytes for output
28 bytes for input
28 bytes for output
FANUC CNC SYSTEM
FANUC Power Mate
/□
32 bytes for input
32 bytes for output
Specify a value of 12, 16, 20, 24, 28 or 32 for
indicating the number of bytes for
input/output.
1 to 8 bytes for input
1 to 8 bytes for output
12 bytes for input
12 bytes for output
16 bytes for input
16 bytes for output
20 bytes for input
20 bytes for output
24 bytes for input
24 bytes for output
28 bytes for input
28 bytes for output
/
32 bytes for input
32 bytes for output
Specify a value of 1 to 8, 12, 16, 20, 24, 28 or
32 for
indicating the number of bytes for
input/output.
OC02I 16 bytes for input
OC02O 16 bytes for output
OC03I 32 bytes for input
I/O Link connection unit
OC03O 32 bytes for output