B-63983EN/02 8.LADDER DIAGRAM MONITOR AND EDITOR SCREENS ([PMC LADDER])
- 825 -
Fig. 8.3.3 (a) Structure of the NET EDITOR screen
(1) Screen structures
(a) It is basically same with LADDER DIAGRAM EDITOR
screen, except that only one net is in this screen, and that
position bar at right edge of screen does not appear at this
screen.
(b) Current edit mode is indicated at right of the top line as
"NEW MODE" or "MODFY MODE". When [ZOOM] soft
key at LADDER DIAGRAM EDITOR screen is used to
reach NET EDITOR screen, the screen is in Modify mode,
and when [CREATE NET] soft key is used, it is in New
mode.
(c) Current net number is displayed at right of the top line. The
net number is same with the net number in previous
LADDER DIAGRAM EDITOR screen.
(d) NET EDITOR screen expands image of net horizontally for
a wider net according to its width, while LADDER
DIAGRAM MONITOR/EDITOR screen folds nets wider
than screen width. When net width is expanded over screen
width, attempt to move cursor out of screen will scroll net
image to the direction.
The net of maximum size occupies area of 1024 elements,
but actually available area may be little less for internal use
according to the internal condition: "element" means the
space that is occupied by single relay.