A.PARAMETERS B-63874EN-1/02
- 298 -
12384 Measurement result storage variable start number
(Default value = 10500)
[Data type] Two-word
[Valid data range] 0 to 99999
Start number for the macro variable area for holding measurement
results
12385 Number of variables for storing measurement results
(Default value = 699)
[Data type] Word
[Valid data range] 0 to 9999
Number of macro variables that can be used to hold measurement
results
NOTE
In connection with parameter No. 12381 to
parameter No. 12385, the number of macro
variables (P-CODE macro variables) that can be
actually used depends on the compile parameter
setting of the machine tool builder. For details, refer
to the manual issued by the machine tool builder.
12386 PMC signal for measurement
(Default value = 951)
[Data type] Word
[Valid data range] 0 to 9999
Parameter used to specify the address of the R signal for PMC used
with the measurement function.
12387 Number for a macro program for selecting a tool
(Default value = 3800)
[Data type] Two-word
[Valid data range] 0 to 99999999
Number representing the user macro program executed when the [TL-
SEL] soft key is pressed
12388 Number for a macro program for making measurements
(Default value = 3600)
[Data type] Two-word
[Valid data range] 0 to 99999999
Number representing the user macro program executed when the
[MESURE] soft key is pressed