Ed.
Date
Design
Description
Name
Draw.
FANUC MANUAL GUIDE i
(Series16i/18i/21i-MB/TB)
OPERATOR’S MANUAL
B-63874EN-1/02-3
Page
FANUC LTD.
13
64
G code format
When the operator press the INSERT key after entering necessary data, a
G-code program in the following format is stored in the machining program
memory:
G2062 Q_ D_ H_ V_ L_ R_ N_ M_ F_ P_ S_ Y_ ;
The following newly G-code are added for this function
G-COD
E
Measurement Cycle
G2062
Stylus Ball Diameter Measurement (PROBE Z-AXIS DIRECTION)
G2162
Stylus Ball Diameter Measurement (PROBE X-AXIS DIRECTION)
G2063
Stylus Ball Center Offset Measurement-A (PROBE Z-AXIS
DIRECTION)
G2163
Stylus Ball Center Offset Measurement-A (PROBE X-AXIS
DIRECTION)
G2064
Stylus Ball Center Offset Measurement-B (PROBE Z-AXIS
DIRECTION)
G2164
Stylus Ball Center Offset Measurement-B (PROBE X-AXIS
DIRECTION)
G2073
Outside Diameter Measurement (PROBE Z-AXIS DIRECTION) WORK
SET
G2173
Outside Diameter Measurement (PROBE X-AXIS DIRECTION) WORK
SET
G2074
Inside Diameter Measurement (PROBE Z-AXIS DIRECTION) WORK
SET
G2174
Inside Diameter Measurement (PROBE X-AXIS DIRECTION) WORK
SET
G2083
Outside Diameter Measurement (PROBE Z-AXIS DIRECTION)
MEASURE
G2183
Inside Diameter Measurement (PROBE Z-AXIS DIRECTION)
MEASURE
G2084
Outside Diameter Measurement (PROBE X-AXIS DIRECTION)
MEASURE
G2184
Inside Diameter Measurement (PROBE X-AXIS DIRECTION)
MEASURE
7.2.2 Other Functions
7.2.2.1 Tool Length Compensation at Measurement cycle
It is possible to execute the measurement cycles with activating the tool
length compensation.
When pressing [SETING] soft key on measurement of probe length, it is set
the measurement result to macro variable for calibration data. At the same
time, it is set the measurement result for tool offset number specified at
parameter No.27247.