B-65270EN/05 4.SERVO FUNCTION DETAILS
- 129 -
1895 (FS15i)
TCMD filter coefficient
2067 (FS30i,16i)
1779 (FS15i)
TCMD filter coefficient for rapid traverse
2156 (FS30i,16i)
[Series30i, 16i, and so on]
Cutting/rapid feed-forward switching function TCMD filter
No. 2156=0 (disabled) Always No. 2067
Rapid traverse
No. 2156
No. 2156≠0 (enabled)
Cutting feed No. 2067
[Series15i]
Cutting/rapid feed-forward switching
function
TCMD filter
No. 1779=0 (disabled) Always No. 1895
Rapid traverse
No. 1779
No. 1779≠0 (enabled)
Cutting feed No. 1895
<3> Switching of the current loop 1/2 PI control function in cutting
feed and rapid traverse
When the cutting/rapid velocity loop gain switching function is
enabled, the current loop 1/2 PI control function is turned off at
the time of rapid traverse. Only when current loop 1/2 PI control
must be used also for rapid traverse while the cutting/rapid
velocity gain switching function is enabled, set the bit for always
enabling the current loop 1/2 PI control function.
#7 #6 #5 #4 #3 #2 #1 #0
1743 (FS15i)
CRPI
2203 (FS30i,16i)
1: Enables the current loop 1/2 PI control function.
0: Disables the current loop 1/2 PI control function.
#7 #6 #5 #4 #3 #2 #1 #0
1742 (FS15i)
VGCCR
2202 (FS30i,16i)
1: Enables the current loop 1/2 PI control function for cutting only.
0: Enables the current loop 1/2 PI control function for both cutting
and rapid traverse.
NOTE
This function bit has double meanings. One is
above and another is the cutting/rapid velocity loop
gain switching function.