B-65270EN/05 4.SERVO FUNCTION DETAILS
- 199 -
<11>Setting a limit to the second stage acceleration amount
Making an optimum override setting for low-speed and
high-speed ranges may result in an insufficient acceleration
amount in a medium-speed range. To avoid this problem, adjust
overriding for low-speed and medium-speed ranges, and set an
optimum value for the high-speed range in the following
parameter as a limit value.
2751 (FS15i)
Limit value for the two-stage backlash second stage acceleration amount
2338 (FS30i, 16i)
[Valid data range] 0 to 32767 (if this parameter is 0, no limit is placed to the second stage
acceleration amount.)
Second stage
acceleration amount
cceleration
Second stage
acceleration amount
Intercept:
N2039
Gradient:
N2114
Measurement
oint A
Second stage
acceleration amount
Limit value:
N2338
Measurement
oint B
Measurement
oint C
If there is no sufficient acceleration amount at measuremen
point B, there remains a quadrant protrusion.
n optimum acceleration amount will be
obtained at all measurement points.
cceleration
Measurement
oint A
Measurement
oint B
Measurement
oint C
Fig. 4.6.7 (f) Override adjustment for the second stage acceleration amount of two-stage backlash acceleration
<12>Direction-specific setting for second stage acceleration
If the optimum second stage acceleration amount varies
depending on the direction in which turn-over occurs, specify the
following parameters.
2752 (FS15i)
2339 (FS30i, 16i)
Two-stage backlash second stage acceleration amount override for
turn-over from the negative direction to the positive direction
[Recommended value] 100
2753 (FS15i)
2340 (FS30i, 16i)
Second stage acceleration amount override for turn-over from the negative
direction to the positive direction
[Valid data range] 0 to 32767
Not used if the two-stage backlash second stage acceleration amount
from the negative direction to the positive direction (parameter No.
2752 (for the Series 15i) and No. 2339 (for the Series 30i, 16i, and so
on)) is 0.
This parameter takes effect when a reverse from the negative direction
to the positive direction takes place if the two-stage backlash second
stage acceleration amount from the negative direction to the positive
direction (parameter No. 2752 (for the Series 15i) and No. 2339 (for
the Series 30i, 16i, and so on)) is not 0.