B-65270EN/05 2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS
- 55 -
(a) For other than servo software Series 9096
#7 #6 #5 #4 #3 #2 #1 #0
1749 (FS15i)
PGAT
2209 (FS16i)
PGAT(#6) The position gain precision optimization function is:
1: To be enabled
0: To be disabled (conventional method)
NOTE
Specify this function for all the simultaneous
contouring axes.
(b) For servo software Series 9096
#7 #6 #5 #4 #3 #2 #1 #0
1804 (FS15i)
PGEX
2000 (FS16i)
PGEX (#4) 1: Enables the position gain setting range expansion function.
0: Disables the position gain setting range expansion function.
The setting of the number of position pulses need not be changed.
If an overflow in the position gain cannot be prevented by this
function, change the CMR.
If the CMR is multiplied by N (integer), multiply also the flexible feed
gear by N. This means that the detection unit is refined to 1/N. So, the
settings of all parameters that need to be set in the detection unit need
to be increased by N.