C.FUNCTION-SPECIFIC SERVO PARAMETERS APPENDIX B-65270EN/05
- 438 -
: Parameters set up automatically or cleared at initialization
Parenthesized parameters : Common parameters that are also used for other functions
Parameter number
FS15i FS30i,16i,etc.
Meaning
2773 2360 Resonance elimination filter 2 : attenuation center frequency
2774 2361 Resonance elimination filter 2 : attenuation bandwidth
2775 2362 Resonance elimination filter 2 : damping
2776 2363 Resonance elimination filter 3 : attenuation center frequency
2777 2364 Resonance elimination filter 3 : attenuation bandwidth
2778 2365 Resonance elimination filter 3 : damping
2779 2366 Resonance elimination filter 4 : attenuation center frequency
2780 2367 Resonance elimination filter 4 : attenuation bandwidth
2781 2368 Resonance elimination filter 4 : damping
2683#3 2270#3
1: Active resonance elimination filter function (applied with resonance
elimination filter 1)
2765 2352 Detection level (active resonance elimination filter)
→ 4.5.2
2611#0 2223#0 1: disturbance elimination filter function
2731 2318 Disturbance elimination filter : gain
2732 2319 Disturbance elimination filter : inertia ratio
2733 2320 Disturbance elimination filter : gain for inverse model
2734 2321 Disturbance elimination filter : filter time constant
2735 2322 Disturbance elimination filter : acceleration feedback limit
→ 4.5.3
1808#2 2003#2 Observer function
1859 2047 Observer coefficient (POA1)
1862 2050 Observer coefficient (POK1)
1863 2051 Observer coefficient (POK2)
1960#1 2018#1 Disable function for observer in the stop state
1730 2119
Disable function for observer in the stop state : judgment level for
stop state
→ 4.5.4
1743#2 2203#2 1: Current loop 1/2 PI control function enabled
1742#1
1742#2
2202#1
2202#2
1: Current loop 1/2 PI control function enabled only in cutting feed
(Common to the cutting/rapid velocity gain switching function)
1: Current loop 1/2 PI control function is always enabled when the
above bit
is used.
2736 2323 Current control PI ratio
→ 4.5.5
→ 4.3
1718 2033 Position feedback pulse count (vibration damping control)
1719 2034 Vibration damping control gain
→ 4.5.6
1709#7 2019#7 Dual position feedback function (optional function)
1861 2049 Dual position feedback function : maximum amplitude
1971 2078 Dual position feedback function : conversion coefficient (numerator)
1972 2079 Dual position feedback function : conversion coefficient (denominator)
1973 2080 Dual position feedback function : primary delay time constant
1974 2081 Dual position feedback function : zero zone
1729 2118
Dual position feedback function : alarm detection level of Semi-Full
error (Only this function can be used even if there is no option.)
1954#5
1954#4
2010#5
2010#4
1: The backlash compensation amount is added to the error counter
on the full-closed side.
1: The pitch error compensation amount is added to the error counter
on the semi-closed side.
1746#4 2206#4
1: The backlash compensation amount and pitch amount are added
to the error counters on both the full- and semi-closed sides.
1742#4 2202#4 1: Improvement of judge on zero width
→ 4.5.7