C.FUNCTION-SPECIFIC SERVO PARAMETERS APPENDIX B-65270EN/05
- 444 -
: Parameters set up automatically or cleared at initialization
Parenthesized parameters : Common parameters that are also used for other functions
Parameter number
FS15i FS30i,16i,etc.
Meaning
1743#5 2203#5
1: Enables the four-times torque command output.
(Small-torque command output can be measured.)
1726 2115
For internal data output: Must be kept at 0.
The output of the SPEED signal (number of revolutions) is disabled.
(Series 9096)
→ 4.14,
Appendix I
1774 2151 Internal data output: Always specify 0. (Series 90B0)
1775 2152 Internal data output: Always specify 0. (Series 90B0)
1776 2153 Internal data output: Always specify 0. (Series 90B0)
→ 4.14
1746#7 2206#7
1: Performs high-speed data output to the check board (Series
90B0).
2613#1 2225#1 1: TCMD signal check board output 1/2 (Series 90B0)
2613#2 2225#2
1: SPEED signal check board output 1/2 (7500 min
-1
/5 V) (Series
90B0)
→ Appendix I
2208#3 - 1: Arbitrary data screen is displayed.
-
DGN353
DGN354
DGN for internal data display
DGN for internal data display
→ 4.14
[Related to simplified frequency characteristics measurement]
2683#7 2270#7 1: Starts disturbance input.
2683#6 2270#6
1: Inputs disturbance for both of an odd-numbered axis and
even-numbered axis simultaneously. (Used for synchronous axes
or tandem axes)
2683#5 2270#5
1: The input waveform of disturbance input is a square wave.
(Usually, select 0: Sine wave.)
2739 2326 Disturbance input gain
2740 2327 Disturbance input start frequency
2741 2328 Disturbance input end frequency
2742 2329 Number of disturbance input measurement points
→ Appendix H