5.DETAILS OF PARAMETERS B-65270EN/05
- 386 -
☆: Parameters set up automatically at initialization
★: Parameters that can be kept at the automatically set values
Parameter number
Series 15i
Series 30i, 16i,
and so on
Details
1896 1821 Reference counter capacity →2.1.3
1825 1825 Position loop gain (position gain) →3.1
1851 1851 Backlash compensation value →4.6.6, 4.6.7
1874 2020
Motor No.
Motor number that can be specified
→ 2.1.2, 4.14.1
Initial setting
1875 2021
Load inertia ratio (LDINT)
Load inertia
× 256
Rotor inertia
Increase velocity loop gain parameters PK1V and PK2V by
(1 + LDINT/256) times
Adjust for individual
machines separately.
1879
1876
1891
2022
2023
2024
Rotation direction of the motor
Number of velocity pulse
Number of position pulse
→ 2.1.2, 4.14.1
Initial setting
1713
1714
1715
2028
2029
2030
Velocity enabling position gain switching
Acceleration-time velocity enabling integral function for low
speed
Deceleration-time velocity enabling integral function for low
speed
→ 4.8.1
→ 4.8.2
→ 4.8.2
1718
1719
2033
2034
Number of position feedback pulses
Vibration damping control gain
→ 4.5.6
1721 2036
Tandem control/damping compensation gain (main axis)
Tandem control/damping compensation phase coefficient
(sub-axis)
→ 4.18.2, 4.16
1724 2039
2-stage backlash acceleration function : stage 2 acceleration
amount
→ 4.6.7
1852
1853
1854
2040
2041
2042
Current loop gain (PK1)
Current loop gain (PK2)
Current loop gain (PK3)
★ Motor-specific
★ Motor-specific
★ Motor-specific
1855 2043 Velocity loop integral gain (PK1V)
1856 2044 Velocity loop proportional gain (PK2V)
☆ Motor-specific
Adjust for individual
machines separately.
1857 2045 Velocity loop incomplete integral gain (PK3V)
☆ Motor-specific
→ 4.7
1858 2046 Velocity loop gain (PK4V)
★ Motor-specific
1859 2047
Observer parameter (POA1)
This parameter is adjusted when the unexpected disturbance
torque detection and two-stage backlash functions are used.
NOTE: If the velocity gain (load inertia ratio) is changed, this
parameter must be re-adjusted.
☆ Motor-specific
→ 4.6.7, 4.12
1860 2048 Backlash acceleration amount
☆ → 4.6.6, 4.6.7
1861 2049 Maximum dual position feedback amplitude
☆ → 4.5.7
1862
1863
2050
2051
Observer gain (POK1)
Observer gain (POK2)
When only the unexpected disturbance torque detection
function is used, these parameters must be changed.
☆ Motor-specific
→ 4.12
1864 2052 Not used
★
1865 2053 Current dead-band compensation (PPMAX)
★ Motor-specific