4.SERVO FUNCTION DETAILS B-65270EN/05
- 160 -
(4) Setting parameters
1718 (FS15i)
2033 (FS30i, 16i)
Number of position feedback pulses for vibration damping control
conversion coefficient
[Valid data range] -32767 to 32767
When 0 is set, this function is disabled.
If a negative value is specified, it is internally read as 10 times the
specified value. (-1000=10000)
When a flexible feed gear (F⋅FG) is used
(In the case of using the A/B phase separate type detector)
Set value = Number of feedback pulses per motor revolution, received from a
separate detector/8
(Example 1)
With a 5 mm/rev ball screw, 0.5 µm/pulse separate detector, and
a detection unit of 1 µm, F
⋅FG = 1/2
Then,
Set value = 10,000/8 = 1250
When a flexible feed gear (F⋅FG) is used
(In the case of using the serial separate type detector)
Set value = Number of feedback pulses per motor revolution, received from a
separate detector (after feedback pulse)/8
(Example 2)
If a flexible feed gear is used under the conditions described in
example 1 above,
Set value = 10,000/8 = 1250
CAUTION
If the above expression is indivisible, set the
nearest integer.
1719 (FS15i)
Vibration-damping control gain
2034 (FS30i, 16i)
[Valid data range] −32767 to 32767
[Standard setting] About 500
This is the feedback gain for vibration damping control.
Adjust the value in increments of about 100, observing the actual
vibration. An excessively large gain will amplify the vibration.
If setting a positive value amplifies the vibration, try setting a negative
value.