5.DETAILS OF PARAMETERS B-65270EN/05
- 380 -
DBS2 (#7) Quick stop type 2 at emergency stop is:
0: Not used.
1: Used .
[Reference item] Subsection 4.11.2
#7 #6 #5 #4 #3 #2 #1 #0
1745 (FS15i)
HDIS HD2O FULDMY
2205 (FS30i, 16i)
FULDMY (#2) The dummy separate detector function is:
0: Not used.
1: Used .
[Reference item] Subsection 4.9.1
HD2O (#3) The quick stop function for hardware disconnection of separate
detector is:
0: Not applied to axes under synchronous control.
1: Applied to axes under synchronous control .
[Reference item] Subsection 4.11.4
HDIS (#4) The quick stop function for hardware disconnection of separate
detector is:
0: Disabled.
1: Enabled.
[Reference item] Subsection 4.11.4
#7 #6 #5 #4 #3 #2 #1 #0
1746 (FS15i)
HSSR
HBSF
2206 (FS30i, 16i)
HBSF (#4) The backlash compensation amount and pitch error compensation
amount are added:
1: Simultaneously for the full-closed and semi-closed sides.
0: Selectively according to the conventional parameter (No. 2010
(Series 16i etc.) and No. 1954 (Series 15i))If this parameter is set
to 1 (enabled), the settings of parameter No. 2010 (Series 16i
etc.) and parameter No. 1954 (Series 15i) are ignored.
[Reference item] Subsection 4.5.7
HSSR (#7) High-speed data output to the check board is:
0: Not performed.
1: Performed.
[Reference item] Appendix I
#7 #6 #5 #4 #3 #2 #1 #0
1747 (FS15i)
PK2D50
2207 (FS30i, 16i)
PK2D50 (#3) Specifies a variable proportional gain function in the stop state as
follows:
0: 75% down.
1: 50% down.
[Reference item] Subsection 4.4.3
[Related parameters] 1730 (15i), 2119 (16i etc.)