B-65270EN/05 5.DETAILS OF PARAMETERS
- 377 -
#7 #6 #5 #4 #3 #2 #1 #0
1960 (FS15i)
PFBCPY OVR8
MOVOBS
RVRSE
2018 (FS30i, 16i)
RVRSE (#0) The signal direction for the separate detector is:
0: Not reversed.
1: Reversed.
Series 90B0 supports the serial type and incremental parallel type.
MOVOBS (#1) The disable function for observer in the stop state is:
0: Not used.
1: Used
[Reference item] Subsection 4.5.4
OVR8 (#2) The stage-2 acceleration amount override format is on the basis of:
0: 4096 .
1: 256.
[Reference item] Subsection 4.6.7
PFBCPY (#7) 1: The motor feedback signal for the main axis is shared by the
sub-axis. (Set this parameter for the sub-axis only.)
[Reference item] Subsection 4.18.5
#7 #6 #5 #4 #3 #2 #1 #0
1709 (FS15i)
DPFB TANDMP
2019 (FS30i, 16i)
TANDMP (#1) The tandem disturbance elimination control function (option) is: Þ
See
0: Not used.
1: Used .
[Reference item] Section 4.16
DPFB(#7) The dual position feedback function (option) is:
0: Not used.
1: Used .
[Reference item] Subsection 4.5.7
[Related parameters] 1971 (15i), 2078 (16i etc.), 1972 (15i), 2079 (16i etc.), 1973 (15i),
2080 (16i etc.)
#7 #6 #5 #4 #3 #2 #1 #0
1740 (FS15i)
P2EX RISCMC ABG0 IQOB OVSP
2200 (FS30i, 16i)
OVSP (#0) A feedback mismatch alarm is:
0: Detected.
1: Not detected.
IQOB (#2) 1: Eliminates the effect of voltage saturation on unexpected
disturbance torque detection.
[Reference item] Subsection 4.12.1