B-65270EN/05 APPENDIX D.PARAMETERS RELATED TO HIGH-SPEED AND HIGH-PRECISION OPERATIONS
- 465 -
(3) When using HRV1 and FAD (Series 21i/0i)
To use AI advanced preview control in the Series 21i/0i (servo
software Series 9096), make the following settings for using HRV1
control and fine acc./dec.
• Parameters that do not usually need tuning so often and can be left at fixed
values
Parameter No.
FS21i
Standard setting value Description
2003#3 1 Enables PI control function
2003#5 1 Enables backlash acceleration
2004 Standard parameter for HRV1 HRV1 current control
2005#1 1 Enables feed-forward
2006#4 1 Uses the latest feedback data for velocity feedback.
2007#6 1 Enables FAD (Fine acc./dec.)
2015#6 1 Enables two-stage backlash acceleration
2016#3 1 Enables variable proportional gain in the stop state
2017#7 1 Enables velocity loop high cycle management function
2018#2 1
Changes the second override format for stage-2 backlash
acceleration.
2040 Standard parameter for HRV1 Current integral gain
2041 Standard parameter for HRV1 Current proportional gain
2092 10000 Advanced preview (position) feed-forward coefficient
2119
2
(detection unit of 1 µm)
20
(detection unit of 0.1µm)
For variable proportional gain function in the stop state :
judgment level for stop state (specified in detection units)
2146 50 Stage-2 backlash acceleration end timer
2202#1 1 Cutting/rapid traverse velocity loop gain variable
2209#2 1 Enables FAD of linear type.
• Parameters whose settings must be changed according to the size of the
machine but needn’t tuning once set up
Standard setting value
Parameter
No.
Standard
setting
Speed
priority I
Speed
priority II
Description
2109 24 16 16 FAD time constant