B-65270EN/05 4.SERVO FUNCTION DETAILS
- 193 -
First, set the value of
[Typical setting]
. Then, while viewing the
arc figure, adjust the first stage acceleration amount
parameter.(Make an adjustment at a low feedrate of about F500.)
First stage acceleration amount (adequate)
(Protrusions caused by machine friction remain,
but these protrusions are corrected later when
second stage acceleration is adjusted.)
First stage acceleration amount (too large)
(Cuts are caused by excessively high
acceleration at the time of reverse motor
rotation.)
Before two-stage backlash acceleration
adjustment
(A delay in reverse motor rotation causes a
protrusion at each area of quadrant switching.)
Fig. 4.6.7 (b) Two-stage backlash acceleration (first stage acceleration amount adjustment)
1975 (FS15i)
Second stage start position (detection unit)
2082 (FS30i, 16i)
[Unit of data] Detection unit
[Typical setting] 10 (For a detection unit of 1
µm)
100 (For a detection unit of 0.1
µm)
NOTE
1 As the second stage start position, the absolute
value of the setting is used.
2 When setting = 0, the specification of 100 is
internally assumed.