B-65270EN/05 4.SERVO FUNCTION DETAILS
- 269 -
Alarm thresholds for unexpected disturbance torque detection are set
in the following parameters:
1997 (FS15i)
2104 (FS30i, 16i)
Unexpected disturbance torque detection threshold for cutting
(This parameter is used both in not switching mode and in switching mode.)
[Valid data range] 0 to 7282
1765 (FS15i)
Unexpected disturbance torque detection threshold for rapid traverse
2142 (FS30i, 16i)
[Valid data range] 0 to 7282
NOTE
1 When the alarm level for cutting is 32767,
unexpected disturbance torque detection is not
performed during cutting.
2 When the alarm level for rapid traverse is 32767,
unexpected disturbance torque detection is not
performed during rapid traverse. When both
parameters are 32767, unexpected disturbance
torque detection is not performed at any time.