A.ANALOG SERVO INTERFACE SETTING PROCEDURE APPENDIX B-65270EN/05
- 422 -
(Reference)
FSSB setting example where an analog servo interface unit is
used
[Setting example 1: Two analog servo axes]
Let the analog servo interface unit be slave 1. Assume that
analog amplifiers are connected behind the analog servo interface
unit, and let them be slaves 2 and 3 sequentially.
CNC
Analog amplifier 1
Analog amplifier 2
FSSB
X-axis
Y-axis
Analog servo
interface unit 1
(Basic unit)
JV11L
JV12L
Slave 1
Slave 2
Slave 3
Parameter No.
(FS15i)
1080 1081 1082 1083 1084 1085 1086 1087 1088 1089
Parameter No.
(FS16i, PMi)
1910 1911 1912 1913 1914 1915 1916 1917 1918 1919
Set value
16 0 1 40 40 40 40 40 40 40
Parameter No.
(FS30i)
14340 14341 14342 14343 to 14357
Set value
64 0 1 -96
Parameter No.
(FS15i)
No.1023 No.1093 No.1094 No.1095
Parameter No.
(FS16i, PMi)
(FS30i)
No.1023 No.1905 No.1936 No.1937
X axis
1 01000000 0 0
Y axis
2 01000000 1 0
Parameter No.
(FS30i)
14376 14377 14378 to 14407
Set value
0 1 32