B-65270EN/05 2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS
- 11 -
(2) Initialization
Start initialization.
Do not power off the NC until step (11).
#7 #6 #5 #4 #3 #2 #1 #0
INITIAL SET BIT PRMC DGPR PLC0
( Note)
Reset initialization bit 1 to 0.
DGPR(#1)=0
After initialization is completed, DGPR (#1) is set to 1.
NOTE
Once initialization has been completed, bit 3
(PRMC) for initialization automatically set to 1.
(Except Series 30i)
(3) Motor ID No. setting
Specify the motor ID number.
Select the motor ID number of a motor to be used according to the
motor model and motor specification (the middle four digits in
A06B-****
-B***) listed in the following tables.
When using servo HRV3 or HRV4 control, perform loading by using
the motor ID number for servo HRV2 control. Loading is possible
with the series and editions listed in the table and later editions.
The mark "x" indicates a value that varies depending on the options
used.
The mark "-" indicates that automatic loading of standard parameters
is not supported as of February, 2005.
NOTE
• Series 30i
Specify the motor ID number for servo HRV2 control.
• Other than the Series 30i
When a pair of the values set in parameter No. 1023 (servo axis number) are
consecutive odd and even numbers, set motor ID numbers for servo HRV control of
the same type.
(Correct examples)
Servo axes when parameter No.1023= 1,2: Motor ID number for servo HRV2 control
Servo axes when parameter No.1023= 3,4: Motor ID number for servo HRV1 control
(Wrong examples)
Servo axes when parameter No.1023= 1: Motor ID number for servo HRV2 control
Servo axes when parameter No.1023= 2,3: Motor ID number for servo HRV1 control