
B-65270EN/05 4.SERVO FUNCTION DETAILS
- 253 -
4.11.4 Quick Stop Function for Hardware Disconnection of Separate
Detector
(1) Overview
This function reduces the stop distance by resetting the velocity
command for a servo motor to 0 when the separate detector for the
servo motor encounters a hardware disconnection condition. It also
causes the other axes to stop sooner than they would when a usual
alarm occurs.
(2) Series and editions of applicable servo software
(Series 30i,31i,32i)
Series 90D0/A(01) and subsequent editions
Series 90E0/A(01) and subsequent editions
(Series 15i-B,16i-B,18i-B,21i-B,0i-B,0i Mate-B,Power Mate i)
Series 9096/A(01) and subsequent editions
Series 90B0/A(01) and subsequent editions
Series 90B1/A(01) and subsequent editions
Series 90B6/A(01) and subsequent editions
(Series 0i-C,0i Mate-C,20i-B)
Series 90B5/A(01) and subsequent editions
(3) Setting parameters
#7 #6 #5 #4 #3 #2 #1 #0
1745 (FS15i)
HDIS HD2O
2205 (FS30i, 16i)
HD2O (#5) Specifies whether to apply the quick stop function for hardware
disconnection of separate detector to axes subjected to synchronous
control, as follows:
1: To apply
0: Not to apply
HDIS (#4) Specifies whether to enable quick stop function for hardware
disconnection of separate detector as follows:
1: To enable
0: To disable