5.DETAILS OF PARAMETERS B-65270EN/05
- 376 -
BZNG (#7) When a separate detector is used, the battery alarm for the built-in
Pulsecoder is:
0: Not ignored.
1: Ignored .
#7 #6 #5 #4 #3 #2 #1 #0
1958 (FS15i)
PK2VDN ABNT
2016 (FS30i, 16i)
ABNT (#0) The unexpected disturbance torque detection function (option) is:
0: Not used.
1: Used .
[Reference item] Subsection 4.12.1
[Related parameters] 1997 (15i), 2104 (16i etc.)
PK2VDN (#3) The variable proportional gain function in the stop state is:
0: Not used.
1: Used .
[Reference item] Subsection 4.4.3
[Related parameters] 1730 (15i), 2119 (16i etc.)
#7 #6 #5 #4 #3 #2 #1 #0
1959 (FS15i)
PK2V25 RISCFF HTNG DBST
2017 (FS30i, 16i)
DBST (#0) The quick stop type 1 at emergency stop is:
0: Not used.
1: Used .
[Reference item] Subsection 4.11.1
[Related parameters] 1883 (15i), 2005 (16i etc.), 1976 (15i), 2083 (16i etc.)
HTNG (#4) In velocity command mode, the hardware disconnection alarm of a
separate detector is:
0: Detected.
1: Ignored .
RISCFF (#5) 0: When RISC is used, the feed-forward response characteristics
remain as is.
1: When RISC is used, the feed-forward response characteristics are
improved.
[Reference item] Subsection 4.6.3
PK2V25 (#7) Velocity loop high cycle management function is:
0: Not used.
1: Used .
[Reference item] Subsection 4.4.1