2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS B-65270EN/05
- 38 -
2.1.6 Setting Parameters When a CZi Sensor is used
(1) Overview
CZi sensors may be used in the following two ways:
<1> Used as a detector for a synchronous built-in servo motor
<2> Used as a separate detector
This subsection explains parameter settings to be made when the
sensor is used in each of these two ways.
The following two types of CZi sensor are available:
Signal interval Number of pulses at setting
CZi512S
512λ/rev 500,000pulse/rev
CZi1024S
1024λ/rev 1,000,000pulse/rev
(2) Series and editions of applicable servo software
(Series 30i,31i,32i)
Series 90D0/A(01) and subsequent editions
Series 90E0/A(01) and subsequent editions
(Series 15i-B,16i-B,18i-B,21i-B,0i-B,0i Mate-B,Power Mate i)
Series 90B0/A(01) and subsequent editions
(*)
Series 90B1/A(01) and subsequent editions
Series 90B6/A(01) and subsequent editions
(*)
(Series 0i-C,0i Mate-C,20i-B)
Series 90B5/A(01) and subsequent editions
(*)
(*) With Series 90B0, 90B5, and 90B6, a CZi sensor cannot be used
as the detector for a synchronous built-in servo motor. (The CZi
sensor can be used as a separate detector.)
(3) Setting parameters (<1> Used as the detector for a synchronous built-in
servo motor)
[Setting AMR]
#7 #6 #5 #4 #3 #2 #1 #0
1806 (FS15i)
0 AMR6 AMR5 AMR4 AMR3 AMR2 AMR1 AMR0
2001 (FS30i,16i)
Set the value listed below according to the detector.
Detector AMR
CZi512S
Set the number of poles of the synchronous built-in servo
motor in binary.
CZi1024S
Set a value obtained by dividing the number of poles of the
synchronous built-in servo motor by 2 in binary.
Setting example:
When an 88-pole synchronous built-in servo motor and the
CZi1024S are used:
Number of poles/2 = 88/2 = 44
→ The binary representation of the above value is 00101100.
This value is set in AMR.